96 Tests PN: C193306
32 Tests PN: C193306T
Components:
1x Ab-conjugated beads (premixed).
96 Tests PN: C193306A. One bottle containing 4.7 mL of the following AimPlex antibody-bead conjugates
32 Tests PN: C193306TA. One bottle containing 1.5 mL of the following AimPlex antibody-bead conjugates:
S4P1 - anti-human Eotaxin
S4P4 - anti-human IP-10
S4P10 - anti-human IL-8
S5P1 - anti-human MCP-1
S5P3 - anti-human MCP-3
S5P7 - anti-human RANTES
2x Biotin-detection Ab (premixed).
96 Tests PN: C193306B. One vial containing 1.25 mL of the following biotinylated antibodies
32 Tests PN: C193306TB. One vial containing 0.45 mL of the following biotinylated antibodies:
Biotin - anti-human Eotaxin
Biotin - anti-human IP-10
Biotin - anti-human IL-8
Biotin - anti-human MCP-1
Biotin - anti-human MCP-3
Biotin - anti-human RANTES
2x NR dAb Diluent.
96 Tests PN: 07NDX21. One vial containing 1.25 mL of biotin detection antibody diluent.
32 Tests PN: 07NDX21T. One vial containing 0.45 mL of biotin detection antibody diluent.
Lyophilized Standard Mix- Human Chemokine 6-Plex.
96 & 32 Tests PN: HG19306. One vial containing lyophilized recombinant Eotaxin, IL-8, IP-10, MCP-1, MCP-3, RANTES.
Standard Info Sheet: Indicates reconstitute volume and standard concentrations.
Basic Kit for Premixed Panels:
1x Streptavidin-PE (SAPE).
96 Tests PN: 07SP0011. One bottle containing 2.5 mL of 1x SAPE.
32 Tests PN: 07SP0011T. One bottle containing 1 mL of 1x SAPE.
10x Reading Buffer.
96 Tests PN: 07RB1. One bottle containing 4 mL of 10x buffer.
32 Tests PN: 07RB1T. One bottle containing 1.5 mL of 10x buffer.
10x Wash Buffer.
96 Tests PN: 07WB1. One vial containing 15 mL of 10x buffer.
32 Tests PN: 07WB1T. One vial containing 5 mL of 10x buffer.
PCR 8-tube Strip.
96 & 32 Tests PN: 07P8T1. 2 strips.
Filter Plate and Lid.
96 & 32 Test PN: 07FPL1. 1 96- well filter plate and 1 plate lid.
Plate Seals.
PN: 07PSR1. 96 Tests: 4 sealers. 32 Tests: 3 sealers.
Application: Optimal antibody pairs and antigen standards for assaying assaying Human Chemokine 6-Plex Panel. To be used in conjunction with the AimPlex Basic Kit for Premixed Panels - 96 Tests (PN: U100005), 32 Tests (PN: U100005T) and a diluent kit. Refer to the AimPlex Multiplex Immunoassay User Manual and kit inserts for the assay procedure.
Storage: 2-8 C in the dark.
Important: Sodium azide forms explosive compounds with heavy metals. These products contain <0.05% (w/w) azide which with repeated contact with lead and copper commonly found in plumbing drains may result in the buildup of shock sensitive compounds. Dispose in accordance with regulations from your institute.
Assay Specifications:
Sample types: Cell culture supernatant, serum, plasma, bodily fluid and tissue/cell lysate
Sensitivity (LODs): Eotaxin, < 5 pg/mL; IL-8, < 1 pg/mL; IP-10, < 3 pg/mL; MCP-1, < 2 pg/mL; MCP-3, < 2 pg/mL; RANTES, < 5 pg/mL.
LLOQs: Eotaxin, < 10 pg/mL; IL-8, < 1 pg/mL; IP-10, < 10 pg/mL; MCP-1, < 5 pg/mL; MCP-3, < 5 pg/mL; RANTES, < 10 pg/mL.
ULOQs: Eotaxin, > 2,000 pg/mL; IL-8, > 1,000 pg/mL; IP-10, > 2,000 pg/mL; MCP-1, > 5,000 pg/mL; MCP-3, > 5,000 pg/mL; RANTES, > 5,000 pg/mL..
Standard dose recovery: 70-130%
Intra-assay CV: < 10%
Inter-assay CV: < 20%
Cross-reactivity of analytes in the Panel: Negligible
Sample volume: 15 µL/test
For Research Use Only. Not for use in diagnostic procedures.